Technical data
- defined preheated double-sided warm start; starting time 1,5 s at AC and DC, reduced heat current after lamp´s start
- constant luminous flux independent of system voltage jitter
- AC Voltage range 194,254 V
- DC Voltage range 176-280 V (Start has to take place at >= 198 V )
- Power factor at about 0,95
- Overvoltage protection 330 V AC, 1h
- Low voltage protection (automatic cutoff)
< 150 V AC / 170V DC
- high temperature range from
-25 Grad C to +50 Grad C
- Use in emergency lighting according to VDE 0108 possible (DC capable)
- able to be dimmed
- Safety cutoff of faulty lamps – Faulty FTLs are identified as such and are not ignited.
- All safety relevant parameters are permanently monitored
- automatic re-start when FTL has been changed
- for lighting fixtures with 110 Degree,
Cut OFF, EOL
- Usable in lighting fixtures with the Class of Protection I and Class of Protection II
- Protection class humidity IP 20
- Temperature protection according EN 61347-2-3 C5e
- Assembling: plug in-Module without wiring
SaveT5Tronic 220-240 V Output 28W:
- effective length 1149 mm incl. FTL
- EB length: 54 mm without plug
- weight:: 0,155 kg incl. FTL
- total ouput: 27,5 W
- power factor about 0,95
- cos phi at 230V750Hz
- tc point: 65°C
- Temp. range in °C: -25°C - + 50°C
SaveT5Tronic 220-240 V Output 35W:
- effective length 1449 mm incl. FTL
- EB length: 54 mm without plug
- weight:: 0,187 kg incl. FTL
- total ouput: 35 W
- power factor about 0,95
- cos phi at 230V750Hz
- tc point: 65°C
- Temp. range in °C: -25°C - + 50°C
Certificates for: CE TÜV according to DIN-VDE 0713-22 and DIN-VDE 0172-22 VDE Energy class EEI = A2 ENEC certificate submitted
|
Harmonic content of the line current (EMC-compatible) (EMC measurement) meets the requirements of European Directives EN 6100-3-2:1995+A I:1998+A2:1998 has the standard of a German Norm, classification VDE 0838
Output management by ASIC Design ASIC (Application specific integrated circuit) is defined as the latest light-management. Energy- and lamp-saving warmstart within 1,5 sec. and a variety of energy-saving features allow the results by the use of SaveT5Tronic
Energy class CELMA EEI = A2 SaveT5Tronic supports the optimum usage of energy with T5 FTLs. After igniting the lamp the heating current is being reduced automatically. With highly reduced coil heating current the T5 FTL is being operated within its specification, which ensures the manufacturer´s lifetime declaration.
Temperature range The tc point is based on the economic lifetime. The declared average lifetime of SaveT5Tronic in hours is 50.000. The failure quota is less than 10% measured at stated conditions; 0,2% failure / 1.000 operating hours.
Noise suppression SaveT5Tronic electronic ballast is fitted with noise suppression according to EN 55015 and EN 55022, reliable operation and uncritical Noise suppression values are guaranteed
Faulty FTL (e.g. coil breakage, gas defect etc.) In case of faulty FTLs the EB shuts off and skips to stand-by mode. After changing the FTL it re-starts automatically.
Dimension + Weight EVG length 57mm / diameter 39mm / 48g Distaler length 28mm / diameter 39mm / 10g Bridge 38mm / diameter 20mm / 4g
Packaging Unit 28 W SaveT5Tronic® 25 Units/carton 35 W SaveT5Tronic® 25 Units/carton
Guarantee Fife years at 3.000 hours burning-time/year
|